Features
– Continuous, on line density monitoring at process conditions
– Accurately measures density of liquids with viscosity up to 2000cSt
– Rigorous factory calibration and testing of the transducer
– Can operate in pressurized tanks
– Immersion in the tanks up to 30 meters
– No moving parts, virtually maintenance-free system
– We also can tune system specification for your specific requirements
– Hazardous area approvals
– Insensitive to liquid level, mix or turbulence
– Large offer of standard product configurations and installation available
LEMIS process use the proven vibrating element technique which is widely accepted as the most accurate method of continuous online density measurement, LEMIS process engineers made new developments by the introducing unique proprietary design of resonant tube sensor allowing accurate measurement of liquid density. An integral high accuracy Pt-1000 probe continuously monitors liquid temperature allowing temperature compensation and future calculation of reference density, concentration or specific gravity. The technology proves high accuracy of measurement and long term calibration stability even in severs operation conditions. It is insensitive to plant vibration, high variation of temperatures, level, mix or turbulence. A choice of wetted parts materials: from stainless steel for general industrial use, Ni-Span-C for most demanding applications, and Hastelloy for applications where ultimate corrosion resistance is required.
Density operating range: | 0…2 g/cm3 (0…2000 kg/m3) |
Accuracy: | ±0.00025 g/cm3 (±0.25 kg/m3) |
Repeatability: | ±0.0001 g/cm3 (±0.1 kg/m3) |
Calibration stability (per year): | < ±0.0001 g/cm3 (< ±0.1 kg/m3) |
Process Temperature Range: | -200°C to +200°C (-328°F to +392°F) |
Temperature Effect: | 0.005 kg/m3/°C automatically compensated |
Ambient Temperature Range: | -40°C to +85°C (-40°F to +185°F) |
– Density, temperature and concentration monitoring in storage tanks – Petroleum products, fuels, lubricants, LPG, LNG – Concentrations of acids or corrosive chemical – Food, Dairy & Beverages – Product identification and consistency – Concentration and dilution measurement – Monitoring of reaction end in reactors – In-tank mixing and blending |
Features
-Simultaneously measures density and viscosity of liquids at process conditions in tanks or reactors
– Insensitive to liquid level, mix or turbulence
– Can operate in open or pressurized tanks
– Immersion at the level up to 30 meters
– No moving parts, virtually maintenance-free system
– Hazardous area approvals
– Rigorous factory calibration and testing
– Large offer of product configurations and installation options
– Flexible data transfer options
LEMIS process DC42 series of process liquid density/viscosity meter is ideal for real-time, in situ monitoring and control applications within the oil and gas, petrochemical, chemical, food processing and other industries.
Use the proven vibrating element technique which is widely accepted as the most accurate method of continuous on line density measurement, LEMIS process engineers did new step ahead introducing unique proprietary design of resonant tube sensor allowing accurate measurement of liquid viscosity along with its density. An integral high accuracy Pt100 probe continuously monitors liquid temperature allowing temperature compensation and future calculation of reference viscosity, density, concentration or specific gravity. The technology proves high accuracy of measurement and long term calibration stability even in sever operation conditions. It is insensitive to plant vibration, high variation of temperatures, level, mix or turbulence.
The new sensor offers to plant engineers the ability to measure simultaneously and continuously both critical variables of the process liquid in one device saving cost of installation and maintenance. The DC42 series covers wide range of density, viscosity and temperature. Numerous installation options give large flexibility to fit various applications. The sensor can be directly inserted into the opening in a tank wall or can be submerged into a tank at desired level up to 30 meters. This technique can be employed in open or pressurized tanks and reactors. Large choice of process connection flanges is available. The meters have approvals for use in hazardous areas.
A choice of wetted parts materials : from stainless steel for general industrial use, Ni-SpanC for most demanding applications, and Hastelloy for applications where ultimate corrosion resistance is required. If you have specific requirements over the standard list, we can tune system specification for your specific needs.
Density operating range: | 0…2 g/cm3 (0…2000 kg/m3) |
Density accuracy: | ±0.00025 g/cm3 (±0.25 kg/m3) |
Repeatability: | ±0.0001 g/cm3 (±0.1 kg/m3) |
Viscosity operating range: | 0…1200 cSt |
Temperature effect: | 0.005 kg/m3/°C automatically compensated |
Process temperature range: | -200°C to +200°C (-328°F to +392°F) |
Sensor: | stainless steel 316L; Ni-Span C; Hastelloy C22 |
– Density monitoring in storage tanks – Petroleum products, fuels and lubricants – In-tank mixing and blending – Paint and ink quality control – Food, dairy products consistency – Concentration and dilution measurement – Monitoring of reaction end in reactors |
Features
– Continuous, online density monitoring at process conditions
– Accurately measures density of liquids with viscosity up to 1200 cSt
– Rigorous factory calibration and testing of the transducer
– Large offer of factory built installation packs
– No moving parts, virtually maintenance-free system
– Hazardous area approvals
– Large offer of standard products configurations available
– We also can tune system specification for your specific requirements
LEMIS process use the proven vibrating element technique which is widely accepted as the most accurate method of continuous online density measurement, LEMIS process engineers made new developments by the introducing unique proprietary design of resonant tube sensor allowing accurate measurement of liquid density. An integral high accuracy Pt-1000 probe continuously monitors liquid temperature allowing temperature compensation and future calculation of reference density, concentration or specific gravity. The technology proves high accuracy of measurement and long term calibration stability even in severs operation conditions. It is insensitive to plant vibration, high variation of temperatures or turbulence. A choice of wetted parts materials: from stainless steel for general industrial use, Ni-Span-C for most demanding applications, and Hastelloy for applications where ultimate corrosion resistance is required.
Density operating range: | 0…3 g/cm3 (0…3000 kg/m3) |
Accuracy: | ±0.00025 g/cm3 (±0.25 kg/m3) |
Repeatability: | ±0.0001 g/cm3 (±0.1 kg/m3) |
Calibration stability (per year): | < ±0.0001 g/cm3 (< ±0.1 kg/m3) |
Process Temperature Range: | -200°C to +200°C (-328°F to +392°F) |
Temperature Effect: | 0.005 kg/m3/°C automatically compensated |
Ambient Temperature Range: | -40°C to +85°C (-40°F to +185°F) |
– Blending operations
– Petroleum products, fuels, lubricants, LPG, LNG
– Food, Dairy & Beverages
– Volumetric to mass flow metering systems
– Pipeline Interface detection
– Process monitoring and control
– Product identification and consistency
– Concentration and dilution measurement
Features
– Straight through flow design
– Simultaneous density and viscosity measurement
– Density accuracy up to 0.00025 g/cm3
– Measures viscosity up to 1000 cP
– Wide temperature range up to 160°C (320°F)
– Automatic temperature compensation
– Standard installation packs easily ties into process
– No moving parts, virtually maintenance-free system
– Rigorous factory calibration and testing
– Hazardous area approvals
– Flexible data transfer options
DC52 series of process meters has been carefully engineered to fit large range of applications within the oil and gas, petrochemical, chemical, food processing and other industries.
Use the proven vibrating element technique that is widely accepted as the most accurate method of continuous online density measurement, LEMIS process engineers did new step ahead introducing unique proprietary design of streamlined resonant tube that is washed on either side by measured liquid. The oscillation period of the vibrating tube and its frequency characteristics depend on behaviour of the measured liquid allowing simultaneous and accurate direct measurement of both density and dynamic viscosity, and future calculation of kinematic viscosity. An integral high accuracy Pt100 temperature probe provides liquid temperature measurement that allows calculation of reference density and viscosity.
The DC52 series sensor made from stainless steel for general industrial use or from Ni-SpanC for most demanding applications asking for ultimate accuracy in wide temperature range.
– Blending and mixing operations – Volumetric to mass flow metering systems – Pipeline Interface detection – Optimization of burners combustion – Process monitoring and control – Product identification and consistency |
Features
– Direct gas density measurement in pipeline
– Automatic temperature compensation
– Increased safety level
– ATEX Hazardous area certification
– Easy installation, low maintenance
DC-60 Density Meter is another instrument of LEMIS process DC series instruments, designed for accurate, continuous monitoring of the technological process. High-accuracy density data for natural gas mixtures are required in entire range of pressure, temperature and compositions encountered in custody transfer. DC-60 provides a continuous monitoring of density and temperature of natural gas in the flow. The gas is passed over the cylinder tube resonance sensor vibrating at its natural frequency. The mass of gas in contact with the vibrating walls vibrates with the cylinder. Depends upon the gas density and, since increasing the vibrating mass decreases the natural frequency of vibration, the gas density is simply determined by measuring the change in sensor resonant frequency. This measurement method provides precise gas density values in seconds.
– Natural gas custody transfer – Gas blending – Gas quality checking |
Features
* Direct density and level measurement
* Record spot density, average per tank
* ATEX Hazloc certifcation
* Safe operation, low maintenance
* At any depths up to 30 meters
* They’re economical and easy to operate
* Measures highly viscous liquids up to 2000 cP
* Rigid construction for heavy duty outdoor operation
* Local results storage and Bluetooth data transfer
* Petroleum industry
* Food & Beverages
* Ethanol production
* Chemical industry
* Pharmaceutical industry
* Cosmetic industries
Features
– Density/concentration measurements up to 12 points
– Temperature measurements up to 12 points
– High accuracy
– Simple installation
– Suitable for very viscous liquids
– Wide range of applications
– Safe operation, low maintenance
– Easy cleaning
– Rigorous factory testing
– Compact design
– Automatic viscosity/temperature compensation
MDM-40 series processes liquid and LPG density also concentration meters are ideal for real-time, in situ monitoring and it controls applications within the oil, liquefied petroleum, petrochemical, chemical, food and many other industries.
Use the proven vibrating element technique which is widely accepted as the most accurate method of continuous on line density measurement, LEMIS process engineers did new step ahead introducing unique proprietary design of resonant tube sensor allowing accurate measurement of liquid viscosity along with its density. An integral high accuracy Pt1000 probe continuously monitors liquid temperature allowing temperature compensation and future calculation of reference viscosity, density, concentration or specific gravity. The technology proves high accuracy of measurement and long term calibration stability even in sever operation conditions. It is insensitive to plant vibration, high variation of temperatures, leve.
The new sensor offers to plant engineers the ability to measure simultaneously and continuously both critical variables of the process liquid in one device saving cost of installation and maintenance.
Density Range | 0 to 3 g/cm³ (0 to 3000kg/m³) |
Density Accuracy | Up to ±0.00025 g/cm³ (up to ±0.25 kg/m³) |
Density Repeatability | Up to ±0.000125 g/cm³ (up to ±0.125 kg/m³) |
Density Resolution | 0.0001 g/cm³ (0.1 kg/m³) |
Temperature Range | -40°C to +85°C (-40°F to +185°F) |
Temperature Accuracy | ±0.1°C (±0.2°F) |
Ambient temperature | -40°C to +85°C (-40°F to +185°F) |
Viscosity compensation | Automatic |
Temperature compensation | Automatic |
– Petroleum industry
– Ethanol productions
– Food & Beverages
– Chemical industry
– Cosmetic industries
– Pharmaceutical industry
Features
– Combined Density, Level and Temperature measurements
– Density sensor insensitive to liquid level
– Can operate in open or pressurised tanks
– Hazardous area approvals
– Rigorous factory calibration and testing
– Data monitoring at industrial touch screen panel
– Complete automation software package
DLG-400 is completely NEW concept of the combine Density and Level detection system. Two different probes has been mounted together to provide high accurate Density, Level and Temperature measurements in seconds.
Simple installation – requires only one mounting flange for both Level and Density probes. No separate cabling required!!!
Use the proven vibrating element technique which is widely accepted as the most accurate method of continuous online density measurement, LEMIS process engineers did new step ahead introducing unique proprietary design of resonant tube sensor allowing accurate measurement of liquid density and magnetostrictive probe for level. An integral high accuracy Pt100 probe continuously monitors liquid temperature allowing temperature compensation and future calculation of reference density. The technology proves high accuracy of measurement and long term calibration stability even in sever operation conditions.
Industrial touch screen panel with LEMIS Automation Software for continuous data monitoring and processing. Equipped with alarm option to prevent high water level in the tank.
DLG-400 is complete fuel management system, which designed to offer the ability to measure simultaneously and continuously both critical variables of the process liquid in one device saving cost of installation and maintenance.
Level Measuring Range: | up to 4000 mm |
Level Measuring Accuracy: | ±1 mm |
Level Measuring Resolution: | 0.3 mm |
Density Operating Range: | 0…2 g/cm3 (0…2000 kg/m3) |
Accuracy: | ±0.00025 g/cm3 (±0.25 kg/m3) |
Repeatability: | ±0.0001 g/cm3 (±0.1 kg/m3) |
Process temperature range: | -40oC to + 85oC |
– Density monitoring in storage tanks – Petroleum products – LPG tanks – Filling station |
Features
– Direct density measurement
– Record level density and average per tank gravity, API, …
– Automatic temperature compensation
– No sampling required
– ATEX Hazloc certification
– Safe operation, low maintenance
Portable Submersible Density meters DM-250 SERIES best suited for liquid density and temperature measurements directly in the storage or process tanks (up to 6 meters depth). No labor extensive and errors critical sampling required. Instead, the sensors of DM-250 SERIES can be submersed at any required level and record spot density and real temperature at that point directly in the liquid. The operation personal can get in minutes the average density in the tank and its density / temperature / level profile, for example, at every meter. Hundreds of measurements can be stored locally and future transferred to a PC or printer via built-in bluetooth connectivity. The DM series has robust design for heavy duty year round indoor or outdoor operation, even in severe climatic conditions at –40°C to +85°C (-40°F to +185°F).
Density range: | 0… 2 g/cm3 (0… 2000 kg/m3) |
Resolution: | 0… 0.0001 g/cm3 (0.1 kg/m3) |
Accuracy: | ±0.0003…±0.0005 g/cm3 (0.3 or 0.5 kg/m3) |
Temperature range: | -40… +85oC |
Depth of submersion: | up to 6 meters |
Intrinsically safe controller: sensor: | ATEX II (2G) EEx ib [ia] IIB T4 ATEX II 1G EEx ia IIB T4 |
Operating time without charging: | Appr. 12 hours |
Temperature compensation: | Automatic |
– Spot density or density/level profile in storage tanks – Products consistency and adulteration check – Density and level control at outlets and delivery points – Level gauges calibration – In-tank blending and mixing control – Molasses density control in ethanol production – Food, milk and diary products – % alcohol check in beverages industry – Petroleum products, fuels, lubricants |
Features
– Direct density measurement
– Record level density and average per tank gravity, API, …
– Automatic temperature compensation
– No sampling required
– ATEX Hazloc certification
– Safe operation, low maintenance
– At any depths up to 30 meters
– Record level density and average per tank
– Record level of liquid
– Rigid construction for heavy duty outdoor operation
– Local results storage and Bluetooth data transfer
Portable Submersible Density meter DM-250.2 best suited for liquid density and temperature measurements directly in the storage or process tanks (up to 30 meters depth). No labor extensive and errors critical sampling required. Instead, the sensor of DM-250.2 is submersed at any required level and record spot density and real temperature at that point directly in the liquid. The operation personal can get in minutes the average density in the tank and its density / temperature / level profile, for example, at every meter. Hundreds of measurements can be stored locally and future transferred to a PC or printer via built-in bluetooth connectivity. The DM series has robust design for heavy duty year round indoor or outdoor operation, even in severe climatic conditions at –40°C to +85°C (-40°F to +185°F). Backlighted LCD facilitates nighttime operation.
Density determination directly in the tanks is faster, easier, more precise and cost effective comparing with conventional technique requiring sampling and use of glass hydrometers by qualified personal. That is why the DM series portable density meters from LEMIS process have found wide application, first of all in oil industry upstream and downstream operations where control of quality (density) and quantity (mass) of petroleum products at movement and storage is very critical. Continually, the DM series gain success in other industries proving obvious advantages and cost effectiveness compare to traditional methods.
– Spot density or density/level profile in storage tanks – Products consistency and adulteration check – Density and level control at outlets and delivery points – Level gauges calibration – In-tank blending and mixing control – Molasses density control in ethanol production – Food, milk and diary products – % alcohol check in beverages industry – Petroleum products, fuels, lubricants |
Features
– Continuous measurements
– Easy cleaning
– High accuracy
– Simple installation
– Suitable for very viscous liquids
– Wide range of applications
– Rigorous factory testing
– Automatic temperature compensation
– Compact design
VDC-30 principle of operation is based on the changing of frequency characteristics of the sensitive element in the measured liquid. Device measures continuously Dynamic Viscosity and Real Density to calculate Kinematic Viscosity of the liquid.
Usually all the industrial measuring systems operate with dynamic viscosity unlike most of laboratories measure kinematic viscosity via capillary viscometers. So it is critically important to compare laboratory measurements with measurements made by process meters and evaluate measuring system`s performance.
Dynamic Viscosity Range | 0.2 to 2000 mPa·s (0.2 to 2000 cP) |
Dynamic Viscosity Accuracy | ±1% (measured value) |
Density Range | 0.5 to 2 g/cm³ |
Density Accuracy | ±0.0002 g/cm³ |
Temperature Range | -20°C to +100°C (-4°F to +212°F) |
Temperature Accuracy | ±0.1°C (±0.2°F) |
Pressure Range | 0 to 10 Bar |
Viscosity Effect | Automatically compensated |
Process Connection | Swage nipple PN 06HB02 VA 1/8”-6 |
Flow Range | 10 to 100 L/h |
Data Handling | Back lighted LCD 4 x 20 |
Power Supply | 24V AC |
Analog Output | 4 – 20 mA |
Digital Output | RS 485; Modbus |
– Marine
– Military applications
– Pharmaceutical, cosmetic industries
– Petroleum industry
– Food & Beverages
Features
*Density Profile
*Ullage Level
*Interface Level
*Temperature Profile
*At any depths up to 30 meters
Density meter DUTI 454 (hereinafter DUTI 454 or device) designed for continuous process measurements of density, level detection, temperature measurement, average value of density measurement, average temperature measurement and corrected density measurement of liquid with max dynamic viscosity up to 1200 cP and process temperature range -40…+85°С (-40…+185°F).
Density Range | 0 to 3 g/cm³ (0 to 3000kg/m³) |
Density Accuracy | Up to ±0.0003 g/cm³ (up to ±0.3 kg/m³) |
Density Repeatability | Up to ±0.00015 g/cm³ (up to ±0.15 kg/m³) |
Density Resolution | 0.0001 g/cm³ (0.1 kg/m³) |
Level measuring range | Up to 30 meters (100ft.) |
Level measurement accuracy: | ±1 mm (±0.004”) |
Temperature Range | -40°C to +85°C (-40°F to +185°F) |
Temperature Accuracy | ±0.1°C (±0.2°F) |
Ambient temperature | -40°C to +60°C (-40°F to +140°F) |
Viscosity compensation | Automatic |
Temperature compensation | Automatic |
– Petroleum industry
– Custody transfer
– Oil industry
– Chemical industry
– Power industry
Features
– Continuous measurements
– Easy cleaning
– High accuracy
– Simple installation
– Suitable for very viscous liquids
– Wide range of applications
– Compact design
– Automatic temperature compensation
– Rigorous factory testing
LEMIS process uses the proven vibrating element technology which is widely accepted as the most accurate of continuous density measurement. It is based on the frequency changing of the sensitive unit and resistance of the built-in temperature sensor in dependence of characteristics of measured liquid. The oscillation period of the sensitive unit mainly depends on density and temperature of measured liquid.
Continuous monitoring optimizes, controls and manages the processes. DC-30 series has a variety of applications, where low flow rate does not allow to install standard high flow systems. PC connection allows distance control for the most critical parameters in such processes as organic synthesis and chemical reactions in reactors.
Density Range | 0.5 to 2 g/cm³ | ||
Density Accuracy | ±0.00025 g/cm³ | ||
Viscosity Effect | Automatically compensated | ||
Pressure Range | 0 to 10 Bar | ||
Temperature Range | -20°C to +100°C (-4°F to +212°F) | ||
Temperature Accuracy | ±0.1°C (±0.2°F) | ||
Process Connection | Swage nipple PN 06HB02 VA 1/8”-6 | ||
Flow Range | 10 to 100 L/h |
– Chemical industry – Pharmaceutical industry – Cosmetic industries – Petroleum industry – Food & Beverages |
Features
– Direct density and viscosity measurement
– Density, reference density, specific gravity, API, …
– Automatic temperature compensation
– No sampling required operation
– ATEX Hazloc certification transfer
– Safe operation, low maintenance
Portable Submersible Density & Viscosity meter VDM-250 SERIES best suited for liquid density, viscosity, concentration and temperature measurements directly in the storage or process tanks (up to 6 meters depth). No labor extensive and errors critical sampling required. Instead, the sensor of VDM-250 SERIES is submersed at any required level and record spot density/viscosity and real temperature at that point directly in the liquid. The operation personal can get in minutes the average density/viscosity in the tank and its density / viscosity / temperature / level profile, for example, at every meter. Hundreds of measurements can be stored locally and future transferred to a PC or printer via built-in bluetooth connectivity. The VDM SERIES has robust design for heavy duty year round indoor or outdoor operation, even in severe climatic conditions at –40°C to +85°C (-40°F to +185°F).
– Spot density and viscosity or density/viscosity/level profile in storage tanks
– Products consistency and adulteration check
– Density, viscosity and level control at outlets and delivery points
– Level gauges calibration
– In-tank blending and mixing control
– Molasses density control in ethanol production
– Food, milk and diary products
– % alcohol check in beverages industry
– Petroleum products, fuels, lubricants
Features
– Direct density and viscosity measurement
– Density, reference density, specific gravity, API, …
– Automatic temperature compensation
– No sampling required operation
– ATEX Hazloc certification transfer
– Safe operation, low maintenance
Portable Submersible Density & Viscosity meter VDM-250 SERIES best suited for liquid density, viscosity, concentration and temperature measurements directly in the storage or process tanks (up to 6 meters depth). No labor extensive and errors critical sampling required. Instead, the sensor of VDM-250 SERIES is submersed at any required level and record spot density/viscosity and real temperature at that point directly in the liquid. The operation personal can get in minutes the average density/viscosity in the tank and its density / viscosity / temperature / level profile, for example, at every meter. Hundreds of measurements can be stored locally and future transferred to a PC or printer via built-in bluetooth connectivity. The VDM SERIES has robust design for heavy duty year round indoor or outdoor operation, even in severe climatic conditions at –40°C to +85°C (-40°F to +185°F). Backlighted LCD facilitates nighttime operation.
– Spot density and viscosity or density/viscosity/level profile in storage tanks
– Products consistency and adulteration check
– Density, viscosity and level control at outlets and delivery points
– Level gauges calibration
– In-tank blending and mixing control
– Molasses density control in ethanol production
– Food, milk and diary products
– % alcohol check in beverages industry
– Petroleum products, fuels, lubricants
Features
– Precise density and temperature in seconds
– Excellent correlation to ASTM D1657
– Small sample volume
– Easy to operate
– Direct density measurement
– Small and compact
– Automatic temperature compensation
– Data transfer to PC via Bluetooth
Unique Portable Density Meter is a new development especially for liquefied petroleum gases (LPG) measuring. It is based on the resonant method of density measurements and uses small sample volume. Obtained results are instantly converted to relative density (15°C or 20°C or 60°F) in accordance with ASTM D1250 tables.
– LPG filling stations
– LPG transfer fiscal
– LPG storage
– Petroleum industry
– Concentration control at outlets and delivery points
Features
– Petroleum industry
– Milk
– Liquor; Beer; Wine
– Fruit juice
– Paint
-Perfumes; Cosmetics
-Oil Products
-Spirits; Alcoholic Solutions
Features
Features
Features
– Direct density measurement
– Record level density and average per tank
– Automatic temperature compensation
– ATEX Hazloc certification
– Safe operation, low maintenance
– Economical and easy to operate
– Measures highly viscous liquids up to 2000 cP
– Local results storage and BLuetooth data transfer
– OLED Display
DM-250.5 consists of a Density sensor DS-200 and a temperature sensor connected to an electronic block. Density sensor is made from SS316 stainless steel, which allows it to be used in all liquid oil products and non-aggressive chemicals.
There are also several material options for measurement of the aggressive substances such as Hastelloy C 22 and a PTFE coating.
The electronic block is housed within a Stainless Steel body which preserves it from the elements. It also has a large weather-proof OLED display.
The operation is simple – a lab worker fills a standard laboratory 1000 ml beaker with a sample and submerges the DM-250.5 sensor in the sample. Press the “ON” button and within seconds the real time Density and Temperature readings will be displayed on the OLED screen.
DM-250.5 also has an option to display relative Density at 15 C, 60 F, etc. The user can set up any measuring units for Density and Temperature too.
DM-250.5 is delivered in a compact carrying case, which enables to user to comfortably travel for any in-field measuring needs.
DM-250.5 is powered by a re-chargeable accumulator that eliminates the need to purchase any replacement batteries. Work time of a fully charged battery is approximately 40 hours.
The received data can be easily sent via Bluetooth to any nearby device – PC, tablet or portable printer.
ATEX II (2G) EEex ib [ia] IIB T4 certification allows the user to conduct the measurements directly in Ex-zones.
DM-250.5 is a new unique, compact, precise, easy to operate and very budget friendly must-have device for your Density measuring needs!
Here are the recommended fields of application:
– Custody Transfers
– Inventory
– Tank farms
– Pipelines
– Barges
– Ships
– Railcars
– Tank Trucks
Recommended for these products:
– All petrochemicals
– Caustic, alkalis
– Acids
– Molasses
– Syrups
– Spirits and distilled spirits
Density Range | 0 to 3 g/cm³ (0 to 3000kg/m³) | |
Density Accuracy | Up to ±0.0003 g/cm³ (up to ±0.3 kg/m³) | |
Density Repeatability | Up to ±0.00015 g/cm³ (up to ±0.15 kg/m³) | |
Density Resolution | 0.0001 g/cm³ (0.1 kg/m³) | |
Temperature Range | -40°C to +85°C (-40°F to +185°F) | |
Temperature Accuracy | ±0.1°C (±0.1°F) | |
Ambient temperature | -40°C to +85°C (-40°F to +185°F) | |
Viscosity compensation |
| |
Temperature compensation | Automatic |
– Petroleum industry – Ethanol production – Food & Beverages – Chemical industry – Cosmetic industries – Pharmaceutical industry |