Coriolis Mass Flow Meters
HEINRICH Coriolis Mass Flow Meters
Coriolis Mass Flow Meter "ECONOMY LINE"
Model: TME
Applications
Metering of liquids and gases, viscous and corrosive media.
Applications: chemical, petrochemical, oil and gas industries
The TME Series is also used for precise dosing, loading and unloading
systems as well as for custody transfer applications.
Technical data
Sensor
End connections: Flanges acc. EN 1092, ASME B16.5, DIN2512
Nominal pressure: PN 40, ASME Cl 150 / 300 / 600 lbs
Process temperature: -40°C to + 180°C (-40°F to +356°F)
Ambient temperature (junction box): -40°C to + 100°C (-40°F to +212°F)
Ingress protection: IP 65 (EN60529), (NEMA 4X )
Wetted parts: 1.4404 (316 L) / 1.4571 (316 Ti)
Secondary containment: cast iron
CE-mark: Pressure Equipment Directive 2014/68/EU
Ranges: 60 kg/h up to 60.000 kg/h (liquid)
Transmitter
Direct or remote mounted
Power supply 19 – 36 VDC, 24 VAC +/- 20%,90 – 265 VAC
- Outputs: galvanically isolated
- analog: 2 x 0/4-20 mA
- Binary 1: active, potential free 24 V=, max. 200 mA
- Passive: optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Frequency: 1 KHz
- Binary 2: passive, optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Status: passive, optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Input binary: counter reset
Ambient temperature: -20°C bis +60°C/+80°C (-4°F to +140°F/176°F)
Ingress protection: IP 68 (EN60529) (NEMA6)
Accuracy: Liquid: ± 0,15%/ ± 0,05% of reading ± zero point stability
Gas: ± 0,5% of reading ± zero point stability
Density (liquid): ± 0,005 g/cm³/ ± 0,003 g/cm³
Volume: ± 0,2% of reading ± zero point stability
Reliability
Robust Design, immune to vibration effects and to pipeline generated stresses, rugged housing (cast iron)
Special features
Simultaneous metering of mass flow, density, temperature and volumetric flow.Inexpensive integrated heating jacket technology: steam, liquid, electrical Removable sensor housing cover
Approvals and certificates
Explosion protection sensor:
circuits intrinsically safe
DMT 01 ATEX E 149 X
II 1/2G EEx ia IIC T6-T2
(Approval for Zone 0 inside flow tubes)
CE-mark: Pressure Equipment Directive 97/23/EG
Explosion protection transmitter:
BVS 05 ATEX E 021 X
Increased safety: EEx e (connection): II (1)2G EEx de [ia] IIC/IIB T6-T3
Explosion proof: EEx d (connection): II (1)2G EEx d [ia] IIC/IIB T6-T3
Signal output / input: intrinsically safe or not intrinsically safe
NEPSI Approval Cert No. GYJ06477
CE-mark: Explosion Protection Directive 94/9/EG
EMC-Directive 89/336/EWG
Material certificates 3.1, 3.2 acc. DIN EN10204:2004
Custody transfer approval
Communication
HART®
Profibus-PA
Modbus RTU (RS 485)
Fieldbus
Coriolis Mass Flow Meter "CLASSIC LINE"
Model: TMU
Applications
Metering of liquids and gases, viscous and corrosive media.
Applications: chemical, petrochemical, oil and gas, food and pharmaceutical industries.
The TMU Series is also used for precise dosing, loading and unloading systems as well as for custody transfer applications.
Technical data
Sensor
End connections: Flanges acc. EN 1092, ASME B16.5, DIN2512, JIS, NPT (others on request)
Nominal pressure: PN 40, ASME Cl 150 / 300 / 600 (others on request)
Process temperature: -40°C to + 260°C (-40°F to +500°F)
Ambient temperature (junction box): -40°C to + 100°C (-40°F to +212°F)
Ingress protection: IP 66 / IP 68 (EN60529), (NEMA 4X /6)
Wetted parts:
Flow tubes, splitter, flanges: 1.4404 (316 L) / 1.4571 (316 Ti) Hastelloy C-22
Secondary containment: 1.4301 (304) up to TMU040,
St 37.2 / 1.4301 from TMU050
CE-mark: Pressure Equipment Directive 97/23/EG
Ranges: 60 kg/h up to 2.200.000 kg/h (liquid)
Transmitter
Direct or remote mounted
Power supply 19 – 36 VDC, 24 VAC +/- 20%,90 – 265 VAC
- Outputs: galvanically isolated
- analog: 2 x 0/4-20 mA
- Binary 1: active, potential free 24 V=, max. 200 mA
- Passive: optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Frequency: 1 KHz
- Binary 2: passive, optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Status: passive, optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Input binary: counter reset
Ambient temperature: -20°C bis +60°C/+80°C (-4°F to +140°F/176°F)
Ingress protection: IP 68 (EN60529) (NEMA6)
Accuracy: Liquid: ± 0,1%/ ± 0,15%/ of reading ± zero point stability
Gas: ± 0,5% of reading ± zero point stability
Density (liquid): ± 0,005 g/cm³/ ± 0,001 g/cm³
Volume: ± 0,2% of reading ± zero point stability
Approvals and certificates
Explosion protection sensor:
circuits intrinsically safe
DMT 01 ATEX E 149 X
II 1/2G EEx ia IIC T6-T2
(Approval for Zone 0 inside flow tubes)
CE-mark: Pressure Equipment Directive 97/23/EG
Explosion protection transmitter:
BVS 05 ATEX E 021 X
Increased safety: EEx e (connection): II (1)2G EEx de [ia] IIC/IIB T6-T3
Explosion proof: EEx d (connection): II (1)2G EEx d [ia] IIC/IIB T6-T3
Signal output / input: intrinsically safe or not intrinsically safe
NEPSI Approval Cert No. GYJ06477
CE-mark: Explosion Protection Directive 94/9/EG
EMC-Directive 89/336/EWG
Material certificates 3.1, 3.2 acc. DIN EN10204:2004
Custody transfer approval
Communication
HART®
Profibus-PA
Modbus RTU (RS 485)
Fieldbus
Special features
- Extreme large measuring range up to 2.200.000 kg/h.
- Efficient heating jacket technology: steam, liquid, electrical
- Thick walled stainless steel sensor housing
Reliability
Robust Design, immune to vibration effects and to pipeline generated stresses.
Coriolis Mass Flow Meter "UNIVERSAL LINE"
Model: TM
Applications
Metering of liquids and gases, viscous and corrosive media..
Applications: chemical, petrochemical, oil and gas, food and pharmaceutical industries. The TM Series is also used for precise dosing, loading and unloading systems as well as for custody transfer applications.
Technical data
Sensor
End connections: Flanges acc. EN 1092, ASME B16.5, DIN2512, JIS, NPT (others on request)
Nominal pressure: PN 40, ASME Cl 150 / 300 / 600 lbs (standard),
900 bar (special design)
Ambient temperature: direct mounted transmitter:-40°C to + 60°C/+80°C
Remote transmitter: :-40°C to + 100°C
Ingress protection: IP 65 / IP 68 (EN60529), (NEMA 4X / 6)
Wetted parts: 1.4404 (316 L) / 1.4571 (316 Ti), Hastelloy C-22,
Hastelloy B-2, Monel, Nickel, Tantalum (others on request)
Secondary containment: 1.4301 (304 L)/Al TM025, St 37.2/Al / 1.4301 TM050, pressure-resistant version, welded or screwed
CE-mark: Pressure Equipment Directive 97/23/EG
Ranges: 0,8 kg/h up to 40.000 kg/h (liquid)
Transmitter
Direct or remote mounted
Power supply 19 – 36 VDC, 24 VAC +/- 20%,90 – 265 VAC
- Outputs: galvanically isolated
- analog: 2 x 0/4-20 mA
- Binary 1: active, potential free 24 V=, max. 200 mA
- Passive: optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Frequency: 1 KHz
- Binary 2: passive, optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Status: passive, optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Input binary: counter reset
Ambient temperature: -20°C bis +60°C/+80°C (-4°F to +140°F/176°F)
Ingress protection: IP 68 (EN60529) (NEMA6)
Accuracy: Liquid: ± 0,1%/ ± 0,05% of reading ± zero point stability
Gas: ± 0,5% of reading ± zero point stability
Density (liquid): ± 0,005 g/cm³/ ± 0,003 g/cm³
Volume: ± 0,2% of reading ± zero point stability
Approvals and certificates
Explosion protection sensor:
circuits intrinsically safe
DMT 01 ATEX E 149 X
II 1/2G EEx ia IIC T6-T2
(Approval for Zone 0 inside flow tubes)
CE-mark: Pressure Equipment Directive 97/23/EG
Explosion protection transmitter:
BVS 05 ATEX E 021 X
Increased safety: EEx e (connection): II (1)2G EEx de [ia] IIC/IIB T6-T3
Explosion proof: EEx d (connection): II (1)2G EEx d [ia] IIC/IIB T6-T3
Signal output / input: intrinsically safe or not intrinsically safe
NEPSI Approval Cert No. GYJ06477
CE-mark: Explosion Protection Directive 94/9/EG
EMC-Directive 89/336/EWG
Material certificates 3.1, 3.2 acc. DIN EN10204:2004
Custody transfer approval
Communication
HART®
Profibus-PA
Modbus RTU (RS 485)
Fieldbus
Special features
- Simultaneous metering of mass flow, density, temperature and volumetric flow.
- Variety of special materials Integrated heating jacket technology: steam, liquid, flange to flange, electrical Process temperature:-90°C, +260°C
- Pressure rating: up to 900 bar
- Housing: pressure-resistant version welded or screwed
Reliability
Robust Design, immune to vibration effects and to pipeline generated stresses
Coriolis Mass Flow Meter "SLIM LINE"
Model: TMR
Applications
Metering of liquids, Gases and viscous media in the chemical, petrochemical and oil industry. The TMR Series is designed specifically to replace mechanical volumetric type meters. Compared to those meters the flow sensors of the TMR series are maintenance free, wear free and require no filters to protect against solids.
The TMR Series is also used for loading and unloading systems, precise dosing applications.(custody transfer approval in preparation)
Technical data
Sensor
End connections:
Flanges acc. EN 1092, ANSI B16.5, DIN2512
Nominal pressure: PN 40, ASME Cl150 / 300 / 600 (standard)
Process temperature: -40°C to +260°C (-40°F to +500°F)
Ambient temperature junction box: -40°C to + 100°C (-40°F to +212°F)
Ingress protection: IP 68 (EN60529) (NEMA 6)
Wetted parts:
Flow tubes, splitters, flanges:1.4404 (316 L) / 1.4571 (316 Ti)
Housing: 1.4404 (316 L) / 1.4571 (316 Ti), 1.4301 (304 L) up to TMR040, St 37.2 / 1.4301 from TMR080
CE-mark: Pressure Equipment Directive 97/23/EC
Range:
from 120 kg/h up to 120.000 kg/h (liquid)
Transmitter
Direct or remote mounted
Power supply 19 – 36 VDC, 24 VAC +/- 20%,90 – 265 VAC
- Outputs: galvanically isolated
- analog: 2 x 0/4-20 mA
- Binary 1: active, potential free 24 V=, max. 200 mA
- Passive: optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Frequency: 1 KHz
- Binary 2: passive, optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Status: passive, optocoupler Ui=30 V, Ii=200mA, Pi=3 W
- Input binary: counter reset
Ambient temperature: -20°C bis +60°C/+80°C (-4°F to +140°F/176°F)
Ingress protection: IP 68 (EN60529) (NEMA6)
- Accuracy: Liquid: ± 0,15%/ ± 0,05% of reading ± zero point stability
- Gas: ± 0,5% of reading ± zero point stability
- Density (liquid): ± 0,005 g/cm³/ ± 0,003 g/cm³
- Volume: ± 0,2% of reading ± zero point stability
Approvals and certificates
Explosion protection sensor:
circuits intrinsically safe
DMT 01 ATEX E 149 X
II 1/2G EEx ia IIC T6-T2
(Approval for Zone 0 inside flow tubes)
CE-mark: Pressure Equipment Directive 97/23/EG
Explosion protection transmitter:
BVS 05 ATEX E 021 X
Increased safety: EEx e (connection): II (1)2G EEx de [ia] IIC/IIB T6-T3
Explosion proof: EEx d (connection): II (1)2G EEx d [ia] IIC/IIB T6-T3
Signal output / input: intrinsically safe or not intrinsically safe
NEPSI Approval Cert No. GYJ06477
CE-mark: Explosion Protection Directive 94/9/EG
EMC-Directive 89/336/EWG
Material certificates 3.1, 3.2 acc. DIN EN10204:2004
Custody transfer approval (in preparation
Communication
HART®
Profibus-PA
Modbus RTU (RS 485)
Fieldbus
Special features
Replacement of mechanical volumetric type meters without modification of the piping. Due to the integrated density and temperature measurement, this instrument type can be used as a volumetric meter. No filters required. No servicing and recalibration necessary. Transmitter UMC3 can be used in ambient temperatures up to +80°C (hazardous area)
Reliability
Rugged stainless steel housing, immune to vibration effects and to pipeline generated stresses
Coriolis Mass Flow Meter - High Flow
Model: TMU High Flow
Applications
TMU High Flow Coriolis Mass Flow Meter are used where high flow values in piping systems up to 400 mm
/ 32 inch and up to 2,200 t/h have to be measured safely and accurate. The instruments offers a very long term stable zero point, are extremely robust and thus are suitable in particular for applications which can be found in oil and gas loading stations, for measurments in pipline systems on-shore and off-shore. A very special body construction allows the opening of the meter for service works – thus the instruments don´t have to be extracted for most of the inspections needed.
Special features
- Meter sizes up to DN 400 / 32″
- Measuring ranges up to s 2.200 t/h
- Custody transfer approval
- Heating system
- PROFIBUS, FIELBUS, MODBUS – Communication
» for more technical details see also TMU – Classic Line
Coriolis Mass Flow Meter for High Pressure Applications
Model: TM High Pressure HYDROGEN
- Very special High Pressure design
- Pressure resistant up to 1000 bar
- Ranges for hydrogen 3,6 / 5 / 30 kg/min
- Ranges for liquids up to 12,000 kg/h
- Special stainless steel body construction
- Variable transmitter concept
Application:
TM High Pressure Coriolis Mass Flow Meters are specially developed for pro processes where standard Coriolis sensors cannot offer sufficient pressure resistance and measuring performance. TM High Pressure instruments have a special measuring pipe design and offer an excellent zero point stability over the entire pressure range as well as a superior linearity also on changing process pressures. Through usage of special stainless steel alloys and the variability of measuring pipe forms we achieve highest long term stability and process safety. Even in case of process overload – a special sensor housing design e.g. with gas filling or blow out ensures maximum safety.
Typical application areas:
- H2 loading stations / Fuelling stations for vehicles with hydrogen fuel cells
- Injection systems for oil and gas drilling devices
- High pressure hydraulic systems
- Fracking – processes
Special features
- Pressure ranges up to 1000 bar
- Measuring ranges for liquids up to 12.000 kg/h
- Measuring range for hydrogen up to 30 kg / h
- Modular body and measuring pipe design
- Design on customer demands and application
- Heating systems for liquid, steam, and electric
- Variable transmitter concept
- PROFIBUS, FIELDBUS, MODBUS – communication
- -Custody transfer approval
TM – High Pressure Coriolis Mass Flow Meters are the recording of our experience in high pressure Coriolis design over more than a decade. Our High Pressure series does have variable body and measuring pipe concept and therefore we design each single instrument according our customers process and applications details and always specially for the particular case of operation.
Transmitter for Coriolis Mass Flow Meters
Model: UMC 3
- Microcontroller based transmitter
- Remote installation-preamplifier not needed
- LCD-Display
- 4-20 mA HART ®, Profibus, Modbus
Applications
Can be used for all Heinrichs Coriolis Mass Flow Meter Series: TM, TME, TMU and TMR
Technical data
- Installation: Integrated or remote
- Power supply: 19 – 36 VDC, 24 VAC +/- 20%,90 – 265 VAC
- Output: galvanically isolated
- Analog: 2 x 0/4-20 mA
- Binary 1: active, potential free 24 V=, max. 200 mA
- Passive, optocoupler, Ui=30 V, Ii=200mA, Pi=3 W
- Frequency: 1 KHz
- Binary 2: Passive, optocoupler, Ui=30 V, Ii=200mA, Pi=3 W
- Status Passive, optocoupler, Ui=30 V, Ii=200mA, Pi=3 W
- Input binary: Counter reset
Ambient temperature -20°C to +60°C/+80°C
Ingress protection : IP 68 (EN60529) (NEMA6)
Approvals and certificates
Explosion protection: BVS 05 ATEX E 021 X
Increased safty: EEx e (connection): II (1)2G EEx de [ia] IIC/IIB T6-T3
Explosion proof: EEx d (connection): II (1)2G EEx d [ia] IIC/IIB T6-T3
Signal output/ input: intrinsically safe or not intrinsically safe
NEPSI Approval Cert No. GYJ06477
CE-mark: Explosion Protection Directive 94/9/EG
EMC-Directive 89/336/EWG
Options
The control and display unit can be installed separately.
Communication
HART®
Profibus
Foundation Fieldbus
Modbus RTU (RS 485)
Special features
Rugged, durable electronics. Explosion proof dual compartment housing. Integrated or remote installation Permissible ambient temperature in the hazardous area +80°C! Electronics field replaceable without recalibration.
Plug-in data memory module (DSB) for all user data. Configuration via control and display unit No separate handheld terminal required
Transmitter for Coriolis Mass Flow Meters
Model: UMC 4
- Explosion proof housing Ex “d”
- Output signals intrinsically safe or not intrinsically safe
- Integrated control- and display unit
- LCD-Display
- 4-20 mA HART ®
Applications
Can be used for all Heinrichs Coriolis Mass Flow Meter Series: TM, TME, TMU and TMR
Technical data
Installation: Integrated or remote
Power supply: 19 – 36 VDC, 24VAC, 90 – 265 VAC
Signal outputs:
2x analog 4-20 mA (passive)
2x binary (passive)
Ambient temperature: -20°C to +60°C
Ingress protection: IP 68 (EN60529 (NEMA6)
Approvals and certificates
Installation: Integrated or remote
Power supply: 19 – 36 VDC, 24VAC, 90 – 265 VAC
Signal outputs:
2x analog 4-20 mA (passive)
2x binary (passive)
Ambient temperature: -20°C to +60°C
Ingress protection: IP 68 (EN60529 (NEMA6)
Communication
HART®-Protocol
Special features
- Rugged, durable electronics.
- Explosion proof housing.
- Integrated or remote installation
- Electronics field replaceable without recalibration
- Plug-in data memory module (DSB) for all user data.
- Configuration via control and display unit
- No separate handheld terminal required
Coriolis Mass Flow Meter
Model: TMS – CNG
- Pressure ranges up to 500 bar
- Sensor available in 3 sizes – DN10 / DN15 / DN25
- Ranges for CNG up to 500 kg/min
- Ranges for liquids up to 30.000 kg / h
Application:
TMS – CNG Coriolis Mass Flow Meters are specially developed for CNG Dosing processes for custody transfer
applications – but due to the high pressure design also suitable for the machine industry. The sensors are
countedt o have one of the most compact designs on the market and can be delivered in 3 different sizes.
TMS – CNG series characterizes excellent measuring accuracy as well as very high temperature and long term stability, which in particular makes them also suitable for extreme climatical zones. A special sensor housing design allows the filling with different gases and the use of clime or blow -out membranes, which guarantees additional safety in the system.
The adaption to different Coriolis Transmitter Electronics makes the TMS-CNG series a universal usable CNG sensor for OEM applications.
Typical application areas:
- CNG Dosing Facilities / Filling stations for vehicles with natural gas filling
- Mixing systems for PU production
- Hydraulic systems
- Chemical injecting systems for the steel industry
- Fluid systems for the general machine construction
Special Features:
- Pressure ranges up to 500 bar
- Sensor available in 3 sizes – DN10 / DN15 / DN25
- Ranges for CNG up to 500 kg/min
- Ranges for liquids up to 30.000 kg / h
- High variety of process connections
- Design specially for customer applications
- Variable transmitter-concept
- Custody transfer approvals
Coriolis Mass Flow Meter for High Pressure Applications
Model: TM High Pressure Liquid Line
- Very special High Pressure design
- Pressure resistant up to 1000 bar
- Ranges for hydrogen 3,6 / 5 / 30 kg/min
- Ranges for liquids up to 12,000 kg/h
- Special stainless steel body construction
- Variable transmitter concept
Application:
TM High Pressure Coriolis Mass Flow Meters are specially developed for pro processes where standard Coriolis sensors cannot offer sufficient pressure resistance and measuring performance. TM High Pressure instruments have a special measuring pipe design and offer an excellent zero point stability over the entire pressure range as well as a superior linearity also on changing process pressures. Through usage of special stainless steel alloys and the variability of measuring pipe forms we achieve highest long term stability and process safety. Even in case of process overload – a special sensor housing design e.g. with gas filling or blow out ensures maximum safety.
Typical application areas:
- H2 loading stations / Fuelling stations for vehicles with hydrogen fuel cells
- Injection systems for oil and gas drilling devices
- High pressure hydraulic systems
- Fracking – processes
Special Features:
- Pressure ranges up to 1000 bar
- Measuring ranges for liquids up to 12.000 kg/h
- Measuring range for hydrogen up to 30 kg / h
- Modular body and measuring pipe design
- Design on customer demands and application
- Heating systems for liquid, steam, and electric
- Variable transmitter concept
- PROFIBUS, FIELDBUS, MODBUS – communication
- -Custody transfer approval
TM – High Pressure Coriolis Mass Flow Meters are the recording of our experience in hig pressure Coriolis design over more than a decade. Our High Pressure series does have variable body and measuring pipe concept and therefore we design each single instrument according our customers process and applications details and always specially for the particular case of operation.
Coriolis Mass Flow Meter "HPC"
Model: HPC
- For smallest flow rates
- High accuracy +-0.1 % of actual value
- Temperatures up to 180 °C
- Pressure resistant up to 600 bar
- Insensitive to vibrations
- Variable mounting concept
Inline-Version
In-LINE mounting
Wall mounting
Mounting with wall brackets
Desk-Version
Measuring pipes pointing downwards
Desk-Version 2
Measuring pipes pointing upwards
Applications
Metering of liquids and gases, viscous and corrosive media.
Applications: chemical, petrochemical, oil and gas, food and pharmaceutical industries.
Reliability
Very robust flow body in, fitted with 4 sensor coils for
extremely high resolution.
Special Features:
- For smallest flow rates
- High accuracy +-0.1 % of actual value
- Temperatures up to 180 °C
- Insensitive to vibrations
- Variable mounting concept
Technical data
Measuring accuracy:
Liquids: ± 0,1 % of actual
Gases: ± 0,5% of actual
Materials:
Measuring pipes: st.st. 1.4571 (316 TI)
Flow body: st.st. 1.4404 (316 L)
Enclosure cover: aluminum, st.st.
Ranges: 60 kg/h up to 2.200.000 kg/h (liquid)
Process temperature: -40 …+180 °C
Ambient temperature: -20 …+60 °C
Process connection:
G1/2 F, 1/2 NPT F
Gyrolok 6/8/10 mm
Swagelok 6/10/12 mm
Measuring Ranges:
HPC-S01 0-20 kg/h (nom)
HPC-S02 0-50 kg/h (nom)
HPC-S03 0-160 kg/h (nom)
Nominal pressure: PN100 / PN 320 / PN 400
Explosion Approval:
- ATEX 19ATEX2096X BV / IECEx CML 19.0025X Standard
- II 1 G / II 1 D
- Ex ia II C T4 Ga / Ex ia III C T135°C Da
- Tamb.: -40.. to +60°C
- High Temperature
- II 1 G / II 1 D / II 2 D
- Ex ia II C T4..T2 Ga / Ex ia IIIC T135°C Da / Ex ia IIIC T190°C/T240°C Db
- Tamb: -40 to +60°C
Electrical connection: plug Harting HAN ® R 23 ODU Mini Snap®
Electronic transmitter connection:Transmitter UMC 3 / UMC 4
Golden Promise Equipment (GPE)-F1001 SERIES MASS FLOWMETER
GPE Model F1001 series Coriolis Mass Flowmeters are a major advance in mass flow measurement. Coriolis Mass Flowmeters provides outstanding accuracy and repeatability which made it as a standard for variety of industry applications. Our technology emphasized on reliability and accuracy of the product. By optimizing manufacturing process, our products can offer you excellent experience of measurements.
GPE Coriolis Mass Flowmeters are of two types:
- Regular/Common type
- Micro-bend type
• Coriolis Flow Measurement Technology
• Multivariable capability for mass flow rate, volume, density and temperature measurement
• Rugged, robust meters with no moving parts result in minimal maintenance or repair
• Accuracy over a wide flow range from a single meter optimizes plant efficiency
• No flow conditioning or straight pipe runs required making installation simplified and less expensive
• Widest range of Coriolis, density, concentration and net flow measurement devices available
•Flow Range: 16kg/h to 2500t/h
•Connection: Flange/Thread
•Operating Pressure: Customized
•Process Temperature: up to +350°C
•Body Material: 304 Stainless Steel
•Measureing Tube Material: 316L Stainless Steel
•Working Humidity: (5% to 95%) RH@+25°C
•Accuracy: ±0.1%
•Repeatability: ±0.05%
•Protection: IP 65 (IP 67 optional)
•Approvals: CE, Exd (ib)II Ct4
•Pulse Output: 0 to 10 kHz, ±0.001%F.S/°C
•Current Output: 4 to 20mA, ±0.005%F.S/°C
•Power Supply: 85 to 265VAC, 18 to 36VDC
•Density Measuring:
Range:0.2 to 2.0 kg/l,
Repeatability:0.001 kg/l
1. With the micro-bend structure, the pressure loss is relatively low compared with
the common type;
2. And the performance of the micro-bend type mass flowmeter is not easily
affected by mechanical vibration, because its high driving frequency is beyond the
frequency of pump etc..
3. For a certain DN, normally the flange distance of the micro-bend type mass
flowmeter is longer than the one of the common type. And the total height of the
micro-bend type mass flowmeter is lower than the one of the common type.
4. Compare with the micro-bend type mass flowmeter, the common type has higher
accuracy, larger signal output, and wider flowrange.
Generally speaking, the micro-bend type mass flowmeter is more suitable for the
process measurement etc. with not very high accuracy demand, while the common
type is usually applied in the measurement with high accuracy requirement.
The above is only for your reference.
F1001 Coriolis Mass Flow Meter measures the fluid mass flow directly.
The Coriolis measuring principle operates independently of physical fluid properties, such as viscosity and density.
It is a proven technology that has been employed in a wide variety of industries such as petroleum, petrochemical industry, pharmacy, paper making, food and energy, etc.
The typical applications are as follows:
- Batch control
- Blending
- Process control
- Filling and Dosing
- Loading and unloading
- Custody transfer
- Process gas measurement
Liquid Flow Range (KG/H)
Badger Meter Coriolis
RCT1000
Industrial end-users are under growing pressure to increase production from existing facilities. Greater process throughput, quality, profitability, and safety are key objectives. Coriolis meters, which directly measure both mass flow and density, provide the accurate measurements that are necessary to meet these demands.
The Badger Meter RCT1000 Coriolis mass flow meter simultaneously measures true mass flow and density reading. The Coriolis meter identifies flow rate by directly measuring fluid mass over a wide range of temperatures with a high degree of accuracy. For fluids consisting of two liquids or a liquid with suspended solids, it can derive the concentration and mass of each fluid based on the density measurement. The Coriolis flow meter’s unobstructed, open-flow design makes it suitable for a variety of viscous, nonconductive fluids.
FEATURES
- Measures liquids
- Unobstructed open-flow design
- Low-maintenance operation with no free-moving parts
- Modbus RTU, HART, Modbus TCP/IP, EtherNet/IP network options
- Hazardous location options
- Advanced fluid diagnostic tools
- Batching and PID control
ADDITIONAL SPECIFICATIONS
Flash Freezing Food – Liquid C02 Measurement
Pet Food Batching System
Solids Control in Calcium Carbonate Slurry
Homogeneous Suspensions and Slurries
Oils and Fuels
Vegetable Oils and Fats
Adhesives, Glues or Binding Materials
Coatings and Hardeners
Dyes, Fragrances, Vitamins and Other Additives
Petrochemical, Refining & Chemical Metering
Process or Industrial
Test Equipment & Services
Water & Wastewater Treatment