Pressure Gauges, Sensors and Transmitters

Pressure Gauges, Sensors and Transmitters – Heinrichs 2020-12-17T10:17:20+01:00
heinrichs pressure transmitter standard - pas

Pressure Transmitter Standard

Model: PAS

  • High Accuracy: ±0,075% of calibrated Span
  • Measuring of gauge and absolute pressure
  • Span up to 600 bar
  • Process temperature: -30°C bis +120°C

Measuring of gauge and absolute pressure

  • High accuracy: ±0,075 % of calibrated span, optional ±0,04% of calibrated span
  • Rangeability: 100:1
  • Automatic ambient temperature compensation
  • Data configuration with HART® configurator or PC.
  • Isolating diaphragms: 1.4404, Tantalum or Hastelloy C
  • Explosion proof housing
  • Process connection via diaphragm seals, (direct mounted or via capillary tube)
  • Span: -1…1,5 bar up to 0…600 bar
  • Accuracy: ±0,075 % of calibrated span
  • Process temperature: -30 °C…+120 °C
  • Ambient temperature: -40 °C…+85 °C
  • Storage temperature: -40 °C…+85 °C
  • Wetted parts:
  • Isolating diaphragms: 1.4404 (316L), Tantalum, Hastelloy C
  • Process connection: 1.4401, Hastelloy C
  • Fill Fluid: silicone oil or inert fill
  • Electronic housing: aluminum (316L option), explosion proof Ex “d”
  • Ingress protection: IP67
  • Paint: epoxy-polyester or polyurethane
  • Mounting bracket: 2-inch pipe, 1.4301 (304),painted carbon steel with 1.4301 (304)U-bolt
  • Process connections: 1/4-18 NPT female (via adapter)
  • 1/2-14 NPT female
  • Display: 5 Digit LCD
  • Power supply: 12…45 VDC operation, 17,5…45 VDC -HART® communications
  • Maximum load: 250 ohm at 17,5 VDC, 550 ohm at 24 VDC
  • Cable entry: ½”-14 NPT / G ½
  • Output: two wire 4…20 mA HART®, linear

ATEX II 2G Exd IIC T6…T4

Communication

Digital communication with HART® protocol

heinrichs diffential pressure transmitter - pad

Diffential Pressure Transmitter

Model: PAD

  • High Accuracy : ±0.075% of Calibrated Span
  • High Rangeability 100 : 1
  • Continuous Self-Diagnostic Function
  • Automatic Ambient Temperature Compensation

Measurement of absolute pressure, gauge pressure, flow and liquid level

  • High accuracy : ±0.075% of calibrated Span
  • Rangeability 100 : 1
  • Automatic ambient temperature compensation
  • Configuration via hand held terminal or PC
  • Isolating diaphragms 1.4404, Monel, Tantalum or HC
  • Flame proof housing.
  • Connection of various diaphragm seals (direct or via capillaries)
  • Span: 0,75…15 mbar up to 4,137…413,70 bar
  • Accuracy: 0,075 % of calibrated span
  • Process temperature: -40 °C…+120 °C
  • Ambient temperature: -40 °C…+80 °C
  • Storage temperature: -40 °C…+85 °C
  • Wetted parts:
  • Isolating diaphragms: 1.4404 (316L), MoneI, Tantalum, HAST-C
  • Fill fluid: Silicone oil or inert fill
  • Electronics housing: Die cast aluminum, flame proof Ex “d”
  • Ingress protection: IP67
  • Finish: Epoxy-Polyester or Polyurethane
  • Mounting bracket: 2″- pipe, 304 SST or painted carbon steel
  • Process connections: 1/4-18 NPT i, process adapter 1/2-14 NPT (optional)
  • Display: 5 digit LCD
  • Power supply: 11,9…45 VDC, 17,4…45 VDC with HART® communication
  • Max. load: 250 Ohm with 17,4 VDC, 550 Ohm with 24 VDC
  • Conduit: ½”-14 NPT / G ½
  • Output: 2-wire 4…20 mA HART®, linear / square root
  • Frequency: pulse width 10, 50 or 100 ms (selectable)

ATEX Certificate: coming soon

Communication

HART®-Protocol