Tecfluid Electromagnetic Flowmeter 2020-09-02T13:55:07+01:00

Tecfluid Electromagnetic Flowmeters

Series FLOMID

tecfluid electromagnetic flowmeter- flomid series

Series FLOMID - Sensor FLOMID-FX - Converter MBC1

Application Areas

Suitable for flow measurement of liquids with conductivity higher than 20 uS/cm.

Product Description

Electromagnetic flowmeter. Modular design in compact and separate version. Readings are independent of density, viscosity, temperature and liquid pressure. Without moving elements and with a low pressure drop. Suitable for liquids with solids. High chemical resistance. Can be installed in any position, provided that the pipe is always full (in vertical pipes upwards flow is recommended). Low power consumption.

Technical specifications

 
Output 4-20 mA /0 … 1000 Hz.
Totalizer
Flow indication
Batching
 
 
 

 

Measuring range

 

 

  • 10 l/h … 7000 m3/h H2O

 

 
 
 

 

Accuracy

 

 

  • =±0,5% f.e.

 

 
 
 

 

Connections

 

 

  • DN3 … DN500, others on request
  • DIN o ANSI flanges (FLOMID-2FX, FLOMID-4FX)
  • Between flanges DIN or ANSI (FLOMID-0FX)
  • Sanitary connection
  • Others on request

 

 
 
 

 

Materials

 

 

  • Body: EN 1.4404 (AISI 316L)
  • Liner: PP, PVDF, ebonite y PTFE
  • Electrode: Hastelloy C, EN 1.4404, Zr, Ti y Tantalum

 

 
 
 

 

Options

 

 

  • High pressure design on request (only for flange connection)
  • Other flange standard on request
  • HART ™ protocol on request

Series FLOMAT

tecfluid flomat-series 1

Series FLOMID - Sensor FLOMID-FX - Converter MBC1

Application Areas

Suitable for flow measurement of liquids with conductivity higher than 20 uS/cm.

Product Description

Electromagnetic insertion flowmeter. Alternating electromagnetic field for measuring avoids electrolysis. Suitable for big pipe sizes. Modular design in compact and separate version. Readings are independent of density, viscosity, temperature and liquid pressure.
Without moving elements and with a low pressure drop. Suitable for liquids with solids. High chemical resistance. Can be installed in any position, provided that the pipe is always full (in vertical pipes upwards flow is recommended). Low power consumption.

Technical specifications

 
Output 4-20 mA /0 … 1000 Hz.
Totalizer.
Flow indication.
 
 
 

 

Measuring range

 

 

  • 2 m3/h … 113000 m3/h H2O

 

 
 
 

 

Accuracy

 

 

  • =±3,5%

 

 
 
 

 

Connections

 

 

  • DN40 … DN2000
  • TF or DIN flange
  • 2 ¼” BSP Threaded

 

 
 
 

 

Materials

 

 

  • Body: EN 1.4404 (SS 316L), PVDF
  • Sensor head: PVDF
  • Electrodes: Hastelloy C, EN 1.4404, Zr, Ti y Tantalum

 

 
 
 

 

Options

 

 

  • High pressure design on request (only for flange connection)
  • Other flange standard on request.
  • HART ™ protocol on request