![zelentech watercut meters - zt100-f-series](https://assetmatrixenergy.com/wp-content/uploads/2020/12/zelentech-watercut-meters-zt100-f-series.jpg)
ZT100 F-Series
The ZelenTech F-Series is designed to enable usage of spool sections 100% compatible with main lines while the flanged probe (316L or or other austenitic steels) will provide an isokinetic measurement (i.e. it does not create flow distortions leading to measurement errors).
ZelenTech ZT-100 Watercut Monitors (also known as BS&W, OWD, WFM or Water in Oil Analyzers) offers you unmatched flexibility as we offer virtually unlimited number of configurations.
ZelenTech ZT-100 Watercut Meters (BS & W, OWM)
Features
- Automatic Temp Comp
- Built in Density Comp
- HART + Modbus available
- PC Interface
F-SERIES CONFIGURATIONS AND FEATURES
Flanged Models:
- Slip-On Flanges or Weld Neck Flanges.
- ANSI, DIN or JIS Flanges
- Available from 4 inch to 48 inch
- Compatible with any Piping Specification
Measurement Ranges:
- Low Range 0-25%
- Mid Range 0-65%
- High Range 0-100%
Design Features:
- Fully Flanged Design
- Blow-Out Proof Self-Jamming Sensor
- Isokinetic Inline Sensor
- 2-wire Loop powered
- Temperature Compensation
- Optional Density Compensation
NEW FEATURE
New: For large sizes we now give the option of utilizing the retractable I-Series probe instead of the traditional F-Series flow-aligned probe. Trade-off is that the unit will not be fully iso-kinetic, however for large pipe lines servicability without removing the main spool may be of greater value.
INTEGRATED STATIC MIXER
The ZelenTech ZT-100 F-Series can optionally be fitted with an integrated Static Mixer (FM-Series). The mixer will ensure that a well mixed and homogenized stream will reach the sensor. We configure mixer elements and spacing in accordance with standards such as ISO 3171 and API MPMS8.2 to ensure that the sensor will see a truly representative view of what is going on in your pipes.
F-SERIES SPECIFICATION
Parameter | Value |
---|---|
Response time | 1 sec |
Sensitivity | 0.01% |
Repeatability | 0.1% |
Output | 4-20mA + HART |
Power Supply | 24VDC (Loop Powered) |
Power Consumption | 0.66W Max |
Temperature (Media) | +150° C (250 with High Temp Option) |
Temperature (Ambient) | +60° C |
Ingress Protection | IP66 / Nema 4X & 7 |
Measurement Range | 0-25% or 0-100% |
Pressure Rating | Up to Class 1500# |
Nominal Sizes | 4 inch to 48 inch |
Material (Probe) | 316L (Optional Duplex, Monel or other steels) |
Material (Spool) | Standard: A106 Gr B Optional: Any other standard pipe material. |
Seals and electrical insulators | PEEK |
GENERAL DATA
Parameter | Value |
---|---|
Principle of Operation | High Frequency Digital Capacitance |
Resolution (Low Range) | 0.001% |
Accuracy (Low Range) | 0.01% |
Resolution (High Range) | 0.05% |
Accuracy (High Range) | 0.05% |
Repeatability | 0.01% Absolute |
Max Water (Low Range) | 25% |
Max Water (High Range) | 100% |
Temp Compensation Range | >0°C – 180°C |
MECHANICAL DATA
Parameter | Value |
---|---|
Wetted Steel Material | 316L Standard (More exotic materials available) |
Seals | PEEK |
Max. Working Pressure | Up to Class 1500# |
Max. Fluid Temperature | 180°C Standard (240°C Optional) |
Max. Ambient Temperature | 65°C |
Process Connection | ANSI, DIN, JIS |
- ATEX EXD
- GOST EXD
- US/CAN EXD
![zelentech watercut meters - zt100 s-series](https://assetmatrixenergy.com/wp-content/uploads/2020/12/zelentech-watercut-meters-zt100-s-series.jpg)
ZT100 S-Series
The iso-kinetic S-Series provides reliable water content metering in all small pipe applications. The ZT-100 S-Series of Watercut Meters can be installed inline or in bypass. Built to any piping spec in the materials of your choice. For larger pipes also check out the F-Series and the new I-Series of water cut meters.
The ZelenTech ZT-100 Watercut Monitor determines the percent watercut in an oil emulsion without requiring the physical separation of the fluids. The emulsion stream is continuously monitored for capacitance and converted into percentage of water by the Watercut Monitor logic.
ZelenTech ZT-100 Watercut Monitors (also known as BS&W, OWD, WFM or Water in Oil Analyzers) offers you unmatched flexibility as we offer virtually unlimited number of configurations.
ZelenTech ZT-100 Watercut Meters (BS & W, OWM)
Features
- Automatic Temp Comp
- Optional Density Comp
- HART + Modbus available
- PC Interface
S-SERIES SPECIFICATIONS
Parameter | Value |
---|---|
Response time | 1 sec |
Sensitivity | 0.01% |
Repeatability | 0.1% |
Output | 4-20mA + HART |
Power Supply | 24VDC (Loop Powered) |
Power Consumption | 0.66W Max |
Temperature (Media) | +150° C (250 with High Temp Option) |
Temperature (Ambient) | +60° C |
Ingress Protection | IP66 |
Measurement Range | 0-25% or 0-100% |
Nominal Sizes | 1 to 6 inch or DN25 to DN200 |
Material (Standard) | 316L |
Seals and electrical insulators | PEEK |
S-SERIES GENERAL DATA
Parameter | Value |
---|---|
Principle of Operation | High Frequency Digital Capacitance |
Resolution (Low Range) | 0.001% |
Accuracy (Low Range) | 0.01% |
Resolution (High Range) | 0.05% |
Accuracy (High Range) | 0.05% |
Repeatability | 0.01% Absolute |
Max Water (Low Range) | 25% |
Max Water (High Range) | 100% |
Temp Compensation Range | >0°C – 180°C |
S-SERIES MECHANICAL DATA
Parameter | Value |
---|---|
Wetted Steel Material | 316L Standard (More exotic materials available) |
Seals | PEEK |
Max. Working Pressure | Up to Class 1500# |
Max. Fluid Temperature | 180°C Standard (240°C Optional) |
Max. Ambient Temperature | 65°C |
Process Connection | ANSI, DIN, JIS |
S-SERIES CONFIGURATIONS AND FEATURES
Threaded or Flanged Models:
- Slip-On Flanges or Weld Neck Flanges.
- ANSI, DIN or JIS Flanges
- Flange sizes from 1 inch to 8 inch
- NPT, BSP, BSPT
- Threaded sizes from 1 inch to 3 inch
Measurement Ranges:
- Low Range 0-25%
- Mid Range 0-65%
- High Range 0-100%
Design Features:
- Isokinetic Inline Sensor
- 2-wire Loop powered
- Temperature Compensation
- Optional Density Compensation
INTEGRATED STATIC MIXER
The ZelenTech ZT-100 S-Series can optionally be fitted with an integrated Static Mixer (SM-Series). The mixer will ensure that a well mixed and homogenized stream will reach the sensor. We configure mixer elements and spacing in accordance with standards such as ISO 3171 and API MPMS8.2 to ensure that the sensor will see a truly representative view of what is going on in your pipes.
- ATEX EXD
- GOST EXD
- US/CAN EXD
![](https://assetmatrixenergy.com/wp-content/uploads/2020/12/zelentech-watercut-meters-zt100-i-series.jpg)
ZT100 I-Series
The ZelenTech I-Series is a new range of insert Watercut Monitors (also known as BS&W, OWD, WFM or Water in Oil Analyzers) developed in-house. The I-Series is inserted vertically into large lines through a 2 inch or 3 inch nozzle.
For smaller pipes also check out the F-Series and the new S-Series of water cut meters.
The ZelenTech ZT-100 Watercut Monitor determines the percent watercut in an oil emulsion without requiring the physical separation of the fluids. The emulsion stream is continuously monitored for capacitance and converted into percentage of water by the Watercut Monitor logic.
- Inherits functionality and safety from the F-Series.
- Fully Blow-Out Proof Safe design.
- Up to ANSI Class 1500 or 250 barg.
- Retractable.
- Retractable under pressure.
- NEL, ATEX or GOST certifications available.
ZelenTech ZT-100 Watercut Meters (BS & W, OWM)
Features
- Automatic Temp Comp
- Optional Density Comp
- HART + Modbus available
- PC Interface
I-SERIES GENERAL DATA
Parameter | Value |
---|---|
Principle of Operation | High Frequency Digital Capacitance |
Resolution (Low Range) | 0.001% |
Accuracy (Low Range) | 0.01% |
Resolution (High Range) | 0.05% |
Accuracy (High Range) | 0.05% |
Repeatability | 0.01% Absolute |
Max Water (Low Range) | 25% |
Max Water (High Range) | 100% |
Temp Compensation Range | >0°C – 180°C |
I-SERIES SPECIFICATION
Parameter | Value |
---|---|
Response time | 1 sec |
Sensitivity | 0.01% |
Repeatability | 0.1% |
Output | 4-20mA + HART |
Power Supply | 24VDC (Loop Powered) |
Power Consumption | 0.66W Max |
Temperature (Media) | +150° C (250 with High Temp Option) |
Temperature (Ambient) | +60° C |
Ingress Protection | IP66 / Nema 4X & 7 |
Measurement Range | 0-25% or 0-100% |
Pressure Rating | Up to Class 1500# |
Probe entry nozzle sizes | 2 inch or 3 inch |
Line Sizes Nominal Sizes | From 12 inch to 42 inch |
Material (Standard) | 316L (Optional Duplex, Monel or other steels) |
Seals and electrical insulators | PEEK |
I-SERIES MECHANICAL DATA
Parameter | Value |
---|---|
Wetted Steel Material | 316L Standard (More exotic materials available) |
Seals | PEEK |
Max. Working Pressure | Up to Class 1500# |
Max. Fluid Temperature | 180°C Standard (240°C Optional) |
Max. Ambient Temperature | 65°C |
Process Connection | ANSI, DIN |
I-SERIES CONFIGURATIONS AND FEATURES
Flanged Insertion Models:
- Fits in 2 inch or 3 inch nozzles
- ANSI or DIN Flange
- Raised Face or RTJ Flange
- Insertion into lines from 12 inch to 48 inch
- Compatible with any Piping Specification
Measurement Ranges:
- Low Range 0-25%
- Mid Range 0-65%
- High Range 0-100%
Design Features:
- Blow-Out Proof Self-Jamming
- Low Flow distortion
- 2-wire Loop powered
- Temperature Compensation
- Optional Density Compensation
- Retractable
- ATEX EXD
- GOST EXD
- US/CAN EXD
![zelentech watercut meters - zt100 t-series](https://assetmatrixenergy.com/wp-content/uploads/2020/12/zelentech-watercut-meters-zt100-t-series.jpg)
ZT100 T-Series
The ZelenTech T-Series is a new range of insert Watercut Monitors (also known as BS&W, OWD, WFM or Water in Oil Analyzers) developed in-house. The T-Series is primarily designed for insertion into smaller pipes and specifically targeted at Well-Head applications where this type of meters are in common use. The ZT100 T=Series will fit in any 3/4 inch NPT socket previously used for other brands using similar designs.
The T-Series is inserted through a 3/4 inch NPT nipple and complements the I-Series insertion meters that is geared towards large pipes.
The ZelenTech ZT-100 Watercut Monitor determines the percent watercut in an oil emulsion without requiring the physical separation of the fluids. The emulsion stream is continuously monitored for capacitance and converted into percentage of water by the Watercut Monitor logic.
- Inherits functionality and safety from the well proven ZT-100 F, S and I-Series.
- Fully Blow-Out Proof Safe design.
- Up to ANSI Class 600#
- Retractable.
- Retractable under pressure (available soon).
- NEL, ATEX or GOST certifications available.
ZelenTech ZT-100 Watercut Meters (BS & W, OWM)
Features
- Automatic Temp Comp
- Optional Density Comp
- HART + Modbus available
- PC Interface
T-SERIES GENERAL DATA
Parameter | Value |
---|---|
Principle of Operation | High Frequency Digital Capacitance |
Resolution | 0.05% |
Accuracy | 0.05% |
Repeatability | 0.01% Absolute |
Max Water | 100% |
Temp Compensation Range | 0°C – 180°C |
T-SERIES SPECIFICATION
Parameter | Value |
---|---|
Response time | 1 sec |
Sensitivity | 0.01% |
Repeatability | 0.1% |
Output | 4-20mA + HART |
Power Supply | 24VDC (Loop Powered) |
Power Consumption | 0.66W Max |
Temperature (Media) | +150° C (250 with High Temp Option) |
Temperature (Ambient) | +60° C |
Ingress Protection | IP66 / Nema 4X & 7 |
Measurement Range | 0-100% |
Pressure Rating | Up to Class 600# |
Probe entry nozzle sizes | 3/4 inch NPT |
Line Sizes Nominal Sizes | 2 or 3 inch or larger using adapter |
Material (Standard) | 316L (Optional Duplex, Monel or other steels) |
Seals and electrical insulators | PEEK |
T-SERIES MECHANICAL DATA
Parameter | Value |
---|---|
Wetted Steel Material | 316L Standard (More exotic materials available) |
Seals | PEEK |
Max. Working Pressure | Up to Class 600# |
Max. Fluid Temperature | 180°C Standard (240°C Optional) |
Max. Ambient Temperature | 65°C |
Process Connection | 3/4 inch NPT or 2 inch flanged adapter |
T-SERIES CONFIGURATIONS AND FEATURES
3/4 inch NPT Insertion Model:
- Sits through elbows into 2 inch or 3 inch lines.
- Suits larger pipes using adaptors
- Qucik and simple setup
- Compatible with existing 3/4 inch nozzles made for similar instrument designs
- Compatible with any Piping Specification
Measurement Ranges:
- 0-100% water in oil
Design Features:
- Safe Blow-Out Proof Design
- Low Flow distortion
- 2-wire Loop powered
- Temperature Compensation
- Optional Density Compensation
- Retractable
- ATEX EXD
- GOST EXD
- US/CAN EXD
Applications
- Highly Accurate Online Water Cut Measurement
- Temperature compensation
- Optional Density Compensation
- Optional Built-In Flow Conditioning
- 4-20mA, HART, RS-232
- Low power 24 VDC
- Variety of measurement ranges
- Variety of designs
- Variety of certifications
- Detection from 0.01%
- BS&W Analyzer / Probe – Monitor
- Net Oil
- LACT
- Production Wells
- Water Content Reporting
- Crude Oil Analyzer Systems
- Water in Condensate Analysis
- Fiscal Metering Skids
- Oil Transportation
- Tank Truck Unloading
- Ship Unloading
- Bunkering
- Crude Oil Pipelines
- Refined Oil Pipelines
- Oil and Gas Exploration
- Crude Oil Production Facilities
- Offshore Oil Exploration
- Tank Farms
- Oil Terminals
- Refineries
- Crude Oil Fiscal Metering
- Oil Emulsions
- Desalters
- Dewatering
- Separator monitoring