SIGHT GLASSES

sw12

SW12

For monitoring the right operation of a steam trap, in order to avoid leakages of live steam and, consequently, great energy losses, a sight glass is recommended to be installed downstream of the steam trap. The single window SW12 sight glasses have been designed for this particular application.

SIZES

1/2” to 1”

CONNECTIONS

Female threaded ISO 7 Rp or NPT

MAX. OPERATING PRESSURE

12 bar

MAX. OPERATING TEMPERATURE

150 ºC

dw40s.jpg

DW40S

For monitoring the right operation of a steam trap, in order to avoid leakages of live steam and, consequently, great energy losses, a sight glass is recommended to be installed downstream of the steam trap. The double window DW40 sight glasses have been designed for this particular application.

MATERIAL

Carbon steel

SIZES

1/2” to 2“ – DN 15 to DN 50

CONNECTIONS

Threaded ISO 7 Rp or NPT
Flanged EN or ASME

MAX. ALLOWABLE PRESSURE

40 bar

MAX. RELATED TEMPERATURE

280 ºC

dw40ss.jpg

DW40SS

For monitoring the right operation of a steam trap, in order to avoid leakages of live steam and, consequently, great energy losses, a sight glass is recommended to be installed downstream of the steam trap. The double window DW40 sight glasses have been designed for this particular application.

MATERIAL

Stainless steel

SIZES

1/2” to 2” – DN 15 to DN 50

CONNECTIONS

Threaded ISO 7 Rp or NPT
Flanged EN PN40
Flanged ASME Class 150 or 300

MAX. ALLOWABLE PRESSURE

40 bar

MAX. RELATED TEMPERATURE

250 ºC

SCKI

SCKI

The SCKI sight checkers function as both sight glasses and check valves. Installed after the steam trap, the sight checker is a device whose main purpose is to visually check the condition and potential leakages of steam traps.

MATERIAL

Stainless steel

SIZES

1/2” to 1”

CONNECTIONS

Threaded ISO 7 Rp

MAX. OPERATING PRESSURE

10 bar

MAX. OPERATING TEMPERATURE

150 ºC

dw12g-jpg-jpg-202012291538575773

DW12G-SS

For monitoring the right operation of a steam trap, in order to avoid leakages of live steam and, consequently, great energy losses, a sight glass is recommended to be installed downstream of the steam trap. The double window DW12 sight glasses has been designed for this particular application.

MATERIAL

Cast iron and stainless steel

SIZES

DN 15 to DN 150

CONNECTIONS

Flanged EN PN16

MAX. ALLOWABLE PRESSURE

16 bar

MAX. RELATED TEMPERATURE

280 ºC